Back to all solutions

Main sol. J1014

Internal Solution-ID: S5057

Equipment needed: Filter Autoclave Anaerobic workbench
1 Mix components thoroughly and adjust pH to 6.0. Autoclave under a N2-CO2 (4:1, v/v) gas mixture. After cooling, add the following solutions anaerobically and aseptically (autoclaved or *filter-sterilized and store under a N2 atmosphere):
Compound Amount Unit Conc. [g/L] Conc. [mM]
(NH4)2SO4 0.20 g 0.194 1.468
KH2PO4 3.00 g 2.91 21.382
MgSO4 x 7 H2O 0.50 g 0.485 1.968
CaCl2 x 2 H2O 0.25 g 0.242 1.649
Yeast extract 0.50 g 0.485 -
Modified Allen's trace metal solution 1.00 ml - -
Trace vitamins
(*)
10.00 ml - -
Iron(III) citrate solution 100.00 ml - -
Distilled water 900.00 ml - -
L-Cysteine HCl
(25 mM)
10.00 ml - -
FeCl2
(130 mM)
10.00 ml - -
J1014 NASU IRON REDUCER MEDIUM