JCM 841 . PROPIONISPORA MEDIUM

What is this page?
Equipment needed: Anaerobic workbench Autoclave Filter

Final pH: 7.1

Select a strain (optional):

ml
Compound Amount Unit
KH2PO4 0.20 g
NH4Cl 0.25 g
NaCl 1.00 g
MgCl2 x 6 H2O 0.40 g
CaCl2 x 2 H2O 0.15 g
FeCl2 solution 1.00 ml
Trace element solution 1.00 ml
Resazurin 0.50 mg
Yeast extract
(BD-Difco)
1.00 g
Distilled water 900.00 ml
1 Mix components thoroughly and autoclave under a N2-CO2 (4:1, v/v) gas mixture. Aseptically and anaerobically add the following solutions (autoclaved or *filter-sterilized):
Fructose
(10%)
50.00 ml
NaHCO3
(*, 5%)
50.00 ml
Na2S x 9 H2O
(5%)
6.00 ml
2 Adjust pH to 7.0 - 7.2, if necessary.

FeCl2 solution #

1000
Compound Amount Unit
HCl
(7.7 M, 25%)
10.0 ml
FeCl2 x 4 H2O 1.5 g
Distilled water 990.0 ml

Trace element solution #

1000