Back to all solutions

Main sol. 816

Internal Solution-ID: S1656

Equipment needed: Gassing station Autoclave Hungate tubes
Compound Amount Unit Conc. [g/L] Conc. [mM]
Solution A 920 ml - -
Solution B 1 ml - -
Solution C 1 ml - -
Solution D 50 ml - -
Solution E 10 ml - -
Solution F 5 ml - -
Solution G 5 ml - -
Solution H 10 ml - -
1 Sparge solution A with 80% N2 and 20% CO2 gas mixture for 30 - 45 min to make it anoxic, dispense under same gas atmosphere into anoxic Hungate-type tubes or serum vials and autoclave. Solutions B, C, F, G, and H are autoclaved separately under 100% N2 gas. Solution D is autoclaved under 80% N2 and 20% CO2 gas atmosphere and autoclaved. Solution E is prepared under 100% N2 gas atmosphere and sterilized by filtration. To complete the medium appropriate amounts of solutions B to H are added to the sterile solution A in the sequence as indicated. Final pH of the medium should be checked and adjusted to 7.6 with a sterile anoxic stock solution of Na2CO3 (5% w/v), if necessary.
816 SPOROTOMACULUM MEDIUM