Back to all solutions

Main sol. 407

Internal Solution-ID: S828

Equipment needed: Gassing station Hungate tubes Autoclave Filter
Compound Amount Unit Conc. [g/L] Conc. [mM]
Solution A 930 ml - -
Solution B 30 ml - -
Solution C 1 ml - -
Solution D 20 ml - -
Solution E 10 ml - -
Solution F 10 ml - -
1 Add and dissolve ingredients of solution A, adjust pH to 7.2, then sparge medium with 80% N2 and 20% CO2 gas mixture for 30 - 45 min to make it anoxic. Distribute medium under same gas atmosphere into anoxic Hungate-type tubes or serum vials and autoclave. Solution B is autoclaved separately under 80% N2 and 20% CO2 gas atmosphere. Solution C is prepared under 100% N2 gas and sterilized by filtration. Solutions D, E and F are autoclaved under 100% N2 gas. To complete the medium, appropriate amounts of solutions B to F are added to the sterile solution A. Adjust pH of complete medium to 7.2, if necessary.
2 Note: Use 25 - 50% inoculum. Growth can be followed by the clearing of stearate. Maintain cultures at 25°C.
407 SYNTROPHOMONAS SD2 MEDIUM